Review




Structured Review

Hummingbird Diagnostics custom microrna oligonucleotide microarray
Custom Microrna Oligonucleotide Microarray, supplied by Hummingbird Diagnostics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom+microarray/custom+microarray+microrna+oligonucleotide/us12410481-314-5-22
Average 86 stars, based on 1 article reviews
custom microrna oligonucleotide microarray - by Bioz Stars, 2026-11
86/100 stars

Images

Related Articles

Generated:

Article Title: Method of diagnosis, staging and monitoring of melanoma using microRNA gene expression
Article Snippet: Data were generated using a custom microRNA oligonucleotide microarray, based on release 13.0 of the Sanger MirBase; (febit Homo Sapiens miRBase 13.0, Hummingbird Diagnostics, Heidelberg, Germany. .. Data were generated using a custom microRNA oligonucleotide microarray, based on release 13.0 of the Sanger MirBase; (febit Homo Sapiens miRBase 13.0, Hummingbird Diagnostics, Heidelberg, Germany. .. By comparing exact microRNA sequences between the Nanostring nCounter human microRNA codesets and the febit Homo sapiens miRBASE 13.0 platforms, 28 of the 38 genes in MEL38 were matched to the peripheral blood validation dataset.

Article Title: Development and validation of a plasma-based melanoma biomarker suitable for clinical use.
Article Snippet: .. These data were generated using a custom miRNA oligonucleotide microarray, based on version 13.0 of the Sanger MirBase; (febit Homo Sapiens miRBase 13.0, Hummingbird Diagnostics, Heidelberg, Germany). .. These data were generated using a custom miRNA oligonucleotide microarray, based on version 13.0 of the Sanger MirBase; (febit Homo Sapiens miRBase 13.0, Hummingbird Diagnostics, Heidelberg, Germany).

Microarray:

Article Title: Method of diagnosis, staging and monitoring of melanoma using microRNA gene expression
Article Snippet: Data were generated using a custom microRNA oligonucleotide microarray, based on release 13.0 of the Sanger MirBase; (febit Homo Sapiens miRBase 13.0, Hummingbird Diagnostics, Heidelberg, Germany. .. Data were generated using a custom microRNA oligonucleotide microarray, based on release 13.0 of the Sanger MirBase; (febit Homo Sapiens miRBase 13.0, Hummingbird Diagnostics, Heidelberg, Germany. .. By comparing exact microRNA sequences between the Nanostring nCounter human microRNA codesets and the febit Homo sapiens miRBASE 13.0 platforms, 28 of the 38 genes in MEL38 were matched to the peripheral blood validation dataset.

Article Title: Development and validation of a plasma-based melanoma biomarker suitable for clinical use.
Article Snippet: .. These data were generated using a custom miRNA oligonucleotide microarray, based on version 13.0 of the Sanger MirBase; (febit Homo Sapiens miRBase 13.0, Hummingbird Diagnostics, Heidelberg, Germany). .. These data were generated using a custom miRNA oligonucleotide microarray, based on version 13.0 of the Sanger MirBase; (febit Homo Sapiens miRBase 13.0, Hummingbird Diagnostics, Heidelberg, Germany).



Similar Products

94
Illumina Inc genochip 2 0 microarray
Genochip 2 0 Microarray, supplied by Illumina Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom+microarray/iSelect+HD+Custom+BeadChip/pm42828432-377-29-32
Average 94 stars, based on 1 article reviews
genochip 2 0 microarray - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

86
Grace Bio-Labs custom nitrocellulose coated microarray slides
Mean <t>microarray</t> antigen spot intensities from TB-free badger serum samples at two time points following experimental infection. White bars represent TB-free sera; gray bars represent TB-infected sera collected at ( a ) 8 weeks and ( b ) 12–13 weeks post-infection. Mean microarray spot intensities (log 2 -normalized) are shown with 95% confidence interval error bars. Paired-sample t -tests were carried out comparing pre- and post-infection mean spot intensities. Antigens were ranked by BH-adjusted P -values, and the 10 most differential antigens (defined as those with the lowest BH-adjusted P -values) for each comparison group are shown. Significance levels: ns: P ≥ 0.05; *: P < 0.05; **: P < 0.01; and ***: P < 0.001.
Custom Nitrocellulose Coated Microarray Slides, supplied by Grace Bio-Labs, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom+microarray/coated+nitrocellulose+slides/pmc12977535-119-8-12
Average 86 stars, based on 1 article reviews
custom nitrocellulose coated microarray slides - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Hummingbird Diagnostics custom microrna oligonucleotide microarray
Mean <t>microarray</t> antigen spot intensities from TB-free badger serum samples at two time points following experimental infection. White bars represent TB-free sera; gray bars represent TB-infected sera collected at ( a ) 8 weeks and ( b ) 12–13 weeks post-infection. Mean microarray spot intensities (log 2 -normalized) are shown with 95% confidence interval error bars. Paired-sample t -tests were carried out comparing pre- and post-infection mean spot intensities. Antigens were ranked by BH-adjusted P -values, and the 10 most differential antigens (defined as those with the lowest BH-adjusted P -values) for each comparison group are shown. Significance levels: ns: P ≥ 0.05; *: P < 0.05; **: P < 0.01; and ***: P < 0.001.
Custom Microrna Oligonucleotide Microarray, supplied by Hummingbird Diagnostics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom+microarray/custom+microarray+microrna+oligonucleotide/us12410481-314-5-22
Average 86 stars, based on 1 article reviews
custom microrna oligonucleotide microarray - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
PEPperPRINT gmbh custom peptide microarrays
Mean <t>microarray</t> antigen spot intensities from TB-free badger serum samples at two time points following experimental infection. White bars represent TB-free sera; gray bars represent TB-infected sera collected at ( a ) 8 weeks and ( b ) 12–13 weeks post-infection. Mean microarray spot intensities (log 2 -normalized) are shown with 95% confidence interval error bars. Paired-sample t -tests were carried out comparing pre- and post-infection mean spot intensities. Antigens were ranked by BH-adjusted P -values, and the 10 most differential antigens (defined as those with the lowest BH-adjusted P -values) for each comparison group are shown. Significance levels: ns: P ≥ 0.05; *: P < 0.05; **: P < 0.01; and ***: P < 0.001.
Custom Peptide Microarrays, supplied by PEPperPRINT gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom+microarray/peptide+microarrays/us12331122-3204-0-6
Average 90 stars, based on 1 article reviews
custom peptide microarrays - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
PEPperPRINT gmbh pepperchip custom peptide microarray
Dot-plot between anti-CRP antibodies and epitope positivity. The graph displays anti-CRP antibodies versus the number of positive epitopes obtained with <t>microarray-based</t> linear epitope mapping in patients with systemic lupus erythematosus ( n =42). (CRP, C-reactive protein).
Pepperchip Custom Peptide Microarray, supplied by PEPperPRINT gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom+microarray/pepperchip+peptide+microarrays/pmc12119686-100-18-22
Average 90 stars, based on 1 article reviews
pepperchip custom peptide microarray - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
SCIENION non-contact piezoelectric microarray spotter customized for r2r operation s12 sciflexarrayer
Dot-plot between anti-CRP antibodies and epitope positivity. The graph displays anti-CRP antibodies versus the number of positive epitopes obtained with <t>microarray-based</t> linear epitope mapping in patients with systemic lupus erythematosus ( n =42). (CRP, C-reactive protein).
Non Contact Piezoelectric Microarray Spotter Customized For R2r Operation S12 Sciflexarrayer, supplied by SCIENION, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom+microarray/piezoelectric+spotter+sciflexarrayer+s3/pm40277543-89-20-24
Average 90 stars, based on 1 article reviews
non-contact piezoelectric microarray spotter customized for r2r operation s12 sciflexarrayer - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Quansys Biosciences custom three-plex enzyme immunoassay microarray
Dot-plot between anti-CRP antibodies and epitope positivity. The graph displays anti-CRP antibodies versus the number of positive epitopes obtained with <t>microarray-based</t> linear epitope mapping in patients with systemic lupus erythematosus ( n =42). (CRP, C-reactive protein).
Custom Three Plex Enzyme Immunoassay Microarray, supplied by Quansys Biosciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom+microarray/custom+three+plex+enzyme+immunoassay+microarray/pm40147520-98-8-12
Average 90 stars, based on 1 article reviews
custom three-plex enzyme immunoassay microarray - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Thermo Fisher custom-made multiplex solid phase microarray platform
Dot-plot between anti-CRP antibodies and epitope positivity. The graph displays anti-CRP antibodies versus the number of positive epitopes obtained with <t>microarray-based</t> linear epitope mapping in patients with systemic lupus erythematosus ( n =42). (CRP, C-reactive protein).
Custom Made Multiplex Solid Phase Microarray Platform, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom+microarray/custom+made+multiplex+solid+phase+microarray+platform/pm40116570-69-14-19
Average 90 stars, based on 1 article reviews
custom-made multiplex solid phase microarray platform - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Thermo Fisher custom-designed antigen microarray
Dot-plot between anti-CRP antibodies and epitope positivity. The graph displays anti-CRP antibodies versus the number of positive epitopes obtained with <t>microarray-based</t> linear epitope mapping in patients with systemic lupus erythematosus ( n =42). (CRP, C-reactive protein).
Custom Designed Antigen Microarray, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom+microarray/custom+designed+antigen+microarray/pm40118130-62-10-13
Average 90 stars, based on 1 article reviews
custom-designed antigen microarray - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Mean microarray antigen spot intensities from TB-free badger serum samples at two time points following experimental infection. White bars represent TB-free sera; gray bars represent TB-infected sera collected at ( a ) 8 weeks and ( b ) 12–13 weeks post-infection. Mean microarray spot intensities (log 2 -normalized) are shown with 95% confidence interval error bars. Paired-sample t -tests were carried out comparing pre- and post-infection mean spot intensities. Antigens were ranked by BH-adjusted P -values, and the 10 most differential antigens (defined as those with the lowest BH-adjusted P -values) for each comparison group are shown. Significance levels: ns: P ≥ 0.05; *: P < 0.05; **: P < 0.01; and ***: P < 0.001.

Journal: Journal of Clinical Microbiology

Article Title: Proteome microarray-guided identification of mycobacterial antigens and ELISA-based peptide mapping for improved serological detection of Mycobacterium bovis infection in European badgers

doi: 10.1128/jcm.01260-25

Figure Lengend Snippet: Mean microarray antigen spot intensities from TB-free badger serum samples at two time points following experimental infection. White bars represent TB-free sera; gray bars represent TB-infected sera collected at ( a ) 8 weeks and ( b ) 12–13 weeks post-infection. Mean microarray spot intensities (log 2 -normalized) are shown with 95% confidence interval error bars. Paired-sample t -tests were carried out comparing pre- and post-infection mean spot intensities. Antigens were ranked by BH-adjusted P -values, and the 10 most differential antigens (defined as those with the lowest BH-adjusted P -values) for each comparison group are shown. Significance levels: ns: P ≥ 0.05; *: P < 0.05; **: P < 0.01; and ***: P < 0.001.

Article Snippet: Translated proteins and IVTT controls were printed onto custom nitrocellulose-coated microarray slides (Grace Bio-Labs, Bend, OR, USA) using a GeneMachines OmniGrid Accent Microarray Printer.

Techniques: Microarray, Infection, Comparison

Mean microarray antigen spot intensities from TB-infected and BCG-vaccinated badger serum samples. Gray bars represent sera from TB-infected badgers collected 12–13 weeks after experimental infection; white bars represent sera from badgers that received ( a ) a single BCG vaccination or ( b ) two BCG vaccinations. Mean spot intensities (log₂-normalized) are shown with 95% confidence interval error bars. Independent-samples t -tests were used to compare antigen intensities between TB-infected and BCG-vaccinated groups. Antigens were ranked by BH-adjusted P -values, and the 10 most differential antigens (defined as those with the lowest BH-adjusted P -values) for each comparison group are shown; ***: P < 0.001.

Journal: Journal of Clinical Microbiology

Article Title: Proteome microarray-guided identification of mycobacterial antigens and ELISA-based peptide mapping for improved serological detection of Mycobacterium bovis infection in European badgers

doi: 10.1128/jcm.01260-25

Figure Lengend Snippet: Mean microarray antigen spot intensities from TB-infected and BCG-vaccinated badger serum samples. Gray bars represent sera from TB-infected badgers collected 12–13 weeks after experimental infection; white bars represent sera from badgers that received ( a ) a single BCG vaccination or ( b ) two BCG vaccinations. Mean spot intensities (log₂-normalized) are shown with 95% confidence interval error bars. Independent-samples t -tests were used to compare antigen intensities between TB-infected and BCG-vaccinated groups. Antigens were ranked by BH-adjusted P -values, and the 10 most differential antigens (defined as those with the lowest BH-adjusted P -values) for each comparison group are shown; ***: P < 0.001.

Article Snippet: Translated proteins and IVTT controls were printed onto custom nitrocellulose-coated microarray slides (Grace Bio-Labs, Bend, OR, USA) using a GeneMachines OmniGrid Accent Microarray Printer.

Techniques: Microarray, Infection, Comparison

Dot-plot between anti-CRP antibodies and epitope positivity. The graph displays anti-CRP antibodies versus the number of positive epitopes obtained with microarray-based linear epitope mapping in patients with systemic lupus erythematosus ( n =42). (CRP, C-reactive protein).

Journal: Frontiers in Immunology

Article Title: Mapping autoantibody targets of full-length C-reactive protein in systemic lupus erythematosus: importance for neutrophil function and classical complement activation

doi: 10.3389/fimmu.2025.1578372

Figure Lengend Snippet: Dot-plot between anti-CRP antibodies and epitope positivity. The graph displays anti-CRP antibodies versus the number of positive epitopes obtained with microarray-based linear epitope mapping in patients with systemic lupus erythematosus ( n =42). (CRP, C-reactive protein).

Article Snippet: The full sequence of the CRP monomer was printed in 15 a.a sequences with 14 a.a overlap using PEPperCHIP Custom Peptide Microarray (PEPperPRINT ® GmbH, Heidelberg, Germany).

Techniques: Microarray

Heatmap representation of autoreactivity against CRP obtained with microarray-based linear epitope mapping of the full CRP monomer. (A, B) Individual signal intensity of IgG autoantibody reactivity against full-length CRP for subjects with SLE ( n =42) and HBD ( n =11). (C–E) Mean signal intensity of IgG autoantibody reactivity against motifs of full-length CRP comparing anti-CRP negative (anti-CRP–; n =16) vs. anti-CRP positive (anti-CRP+; n =26) patients with SLE, patients with ( n =6) and without ( n =36) active disease, and no damage ( n =20) vs. irreversible organ damage (any organ system; n =22). Each column represents one subject (A, B) or the mean value of a group (C–E) . Each row represents a 15 amino acid long sequence covering the full length of the protein with 14 amino acids overlap and 7 amino acid GS repeats elongated before and after the protein sequence. (CRP, C-reactive protein; HBD, healthy blood donors; SDI, Systemic Lupus International Collaborating Clinics/American College of Rheumatology damage index; SLE, systemic lupus erythematosus; SLEDAI-2K, SLE Disease Activity Index 2000).

Journal: Frontiers in Immunology

Article Title: Mapping autoantibody targets of full-length C-reactive protein in systemic lupus erythematosus: importance for neutrophil function and classical complement activation

doi: 10.3389/fimmu.2025.1578372

Figure Lengend Snippet: Heatmap representation of autoreactivity against CRP obtained with microarray-based linear epitope mapping of the full CRP monomer. (A, B) Individual signal intensity of IgG autoantibody reactivity against full-length CRP for subjects with SLE ( n =42) and HBD ( n =11). (C–E) Mean signal intensity of IgG autoantibody reactivity against motifs of full-length CRP comparing anti-CRP negative (anti-CRP–; n =16) vs. anti-CRP positive (anti-CRP+; n =26) patients with SLE, patients with ( n =6) and without ( n =36) active disease, and no damage ( n =20) vs. irreversible organ damage (any organ system; n =22). Each column represents one subject (A, B) or the mean value of a group (C–E) . Each row represents a 15 amino acid long sequence covering the full length of the protein with 14 amino acids overlap and 7 amino acid GS repeats elongated before and after the protein sequence. (CRP, C-reactive protein; HBD, healthy blood donors; SDI, Systemic Lupus International Collaborating Clinics/American College of Rheumatology damage index; SLE, systemic lupus erythematosus; SLEDAI-2K, SLE Disease Activity Index 2000).

Article Snippet: The full sequence of the CRP monomer was printed in 15 a.a sequences with 14 a.a overlap using PEPperCHIP Custom Peptide Microarray (PEPperPRINT ® GmbH, Heidelberg, Germany).

Techniques: Microarray, Sequencing, Activity Assay